Our Solutions

We measure your field data, analyse it and present it to you clearly.

01

Energy Monitoring and Analysis

We continuously measure and analyse your facility's electricity consumption and reactive energy ratios, so you can see the risk of reactive energy penalties in advance. Works with Modbus-enabled energy analysers, relays and meters.

Readings from your energy analysers, relays and meters are recorded per phase. Reactive ratios are tracked against the penalty limits, so a compensation problem is spotted before the bill arrives.

  • Per-phase voltage, current, cosφ and harmonics
  • Active, inductive and capacitive energy tracking
  • Reactive energy penalty limit tracking
  • Compatible with Modbus devices
etaVision
sample

Good morning Monday, 19 October

SAMPLE LTD.

All 4 sites are operating normally.

LiveUpdated just now10:39

⚡ Today's Consumption

3,470 kWh

↘ 6.2% vs. yesterday

This Month

42,560 kWh

Daily average 2,240 kWh

Open Alarms

0

0 critical · 0 faults

Live Devices

32 / 34

4/4 gateways online

Site Status 4 sites

All →
All 4Attention 0Offline 0
  • Kayseri Central

    MERKEZ · just now

    1,284 kWh21.4 … 22.6 °C
  • Istanbul Branch

    IST · 2 min ago

    965 kWh20.8 … 23.1 °C
  • Production Plant

    TSS · just now

    809 kWh18.4 … 29.2 °C
  • Ankara Branch

    ANK · 1 min ago

    412 kWh21.0 … 22.2 °C

Consumption Trend All sites · kWh

24 Hours7 Days
Total

3,637 kWh

Hourly average

152 kWh

Peak hour

11:00 · 275 kWh

5010015020025030011:0017:0023:0005:00
etaVision

Live MonitoringUpdated just now

Kayseri Central

DevicesRelay Test
Site CodeMERKEZLocationKayseriGatewayGW-001● Live
⚡ Energy Analysers 3 devices🌡 Temperature 18 points
Main Distribution Panel · Energy AnalyserCompensation Panel · Reactive Power Controller

Energy Used in the Last 24 Hours Hourly · kWh

812 kWh

↗ 14% vs. previous 24 hours

Peak hour

09:00 · 57.3 kWh

11:0017:0023:0005:00

Consumption Density Last 7 days · kWh

00:0003:0006:0009:0012:0015:0018:0021:00Tue 13Wed 14Thu 15Fri 16Sat 17Sun 18Mon 19

Daily Consumption Last 14 days · kWh

Daily average

942 kWh

Highest day

Oct 13 · 1,097 kWh

Oct 6Oct 10Oct 14Oct 19

WeekdayWeekendToday (in progress)Average

Phase Imbalance Current · Last 24 hours

Now

1.4%

24-hour average

2.4%

Highest

3.6%

● L1 33%● L2 34%● L3 33%

20% high10% caution11:0017:0023:0005:00
etaVision

Live MonitoringUpdated just now

Production Plant

DevicesRelay Test
Site CodeTSSLocationKayseriGatewayGW-001● Live
⚡ Energy Analysers 3 devices🌡 Temperature 18 points
✓

All Normal

18 points · 3 areas

Lowest

18.4 °C

Pharmaceutical Store · Shelf Section A

Highest

29.2 °C

Panel Room · Compensation Panel

No Data

0

in the last 15 minutes

All 18Server Room 4Panel Room 6Store 8
▤

Server Room

A1 · 2 sensors · ● 10:44

22.8°CAverage

Cabinet 1

● just now

22.4°C

Cabinet 2

● just now

23.1°C

⚡

Electrical Panel Room

A2 · 2 sensors · ● 10:44

28.4°CAverage

Main Distribution Panel

● just now

27.6°C

Compensation Panel

● just now

29.2°C

▦

Pharmaceutical Store

A3 · 2 sensors · ● 10:44

18.8°CAverage

Shelf Section A

● just now

18.4°C

Shelf Section B

● just now

19.1°C

Hourly and daily consumption, consumption density and phase imbalance.

A representative view of the etaVision interface. Values are examples.

02

Capacitor Step Testing

We measure the real kVAr output of every capacitor step in your compensation panel and detect capacity loss and faults.

Steps are switched in one by one and the measured reactive power is compared with each capacitor's rated value. Steps that have lost capacity or failed are reported before penalties arise.

  • kVAr measurement per step
  • Comparison with the rated value
  • Capacity loss and fault detection
03

Temperature Monitoring and Analysis

We continuously monitor temperature-critical points in stores, warehouses and production areas and keep a record of every change.

Temperature sensors placed in cold rooms, warehouses, panel rooms and similar locations connect to a SensorHub, which sends the readings wirelessly to the Gateway. Live values, history and trends are always at hand.

  • Continuous multi-point measurement
  • Live values, history and trends
  • Fast installation with wireless data transfer
04

Integrated Energy and Temperature Monitoring

We collect energy and temperature data through the same device so you can monitor both together on a single platform.

For example, seeing a cold room’s temperature next to its cooling system’s consumption lets you spot inefficient operation early.

  • One device, two kinds of measurement
  • A unified view on one platform

Let's find the right solution for your facility together

Tell us about your site and your needs, and we will work out the right setup and scope for you.

Get a quote